Florida building code truss straps. html>lx

steel ASTM A653 Gr50 G90 Galvanized May 27, 2022 · 5. Whereas ASCE 7-10 contained 4 pressure coefficient (GCp) graphs for roof slopes of 0° to 45°, ASCE 7-16 For content printing within Digital Codes Premium, please utilize the section level printing controls available within the Premium toolbar for each section. 2 2010 FLORIDA BUILDING CODE — RESIDENTIAL WALL CONSTRUCTION For SI: 1 inch = 25. Exterior walls of uni. The Sanibel Code may not reflect new ordinances or amendments to existing ordinances The provisions of this chapter govern the quality, design, fabrication and erection of steel used structurally in buildings or structures. All straps have additional fastener holes. The identification mark of an approved agency in accordance with Section 1703. Unless factory installed, the connection device must be approved by the department pursuant to Rules 344 15C-1. A. 9. the Florida Building Code, Building shall be permitted to be built as one- and two-family dwellings or townhouses. The uplift loads do not account for the Jun 1, 1994 · Fire-retardant-treated lumber and wood structural panels shall be labeled. Two story townhome (Orlando, FL). Concrete block first floor, wood frame second. 10. Grout-filled CMU (GFCMU) shall have a minimum compressive strength of f' m = 1,500 psi. 7 mm) airspace on top, sides and end, unless naturally durable or preservative-treated wood is used. Less than 1/2” sideways gap between connection points. Min. ‐ Existing Building‐ Section 1601. 76846 (CA) Created by Independent Third Party: Yes Evaluation Reports Mar 1, 2022 · 101. 1), adopt by reference the ANSI/TPI 1-2002, National Design Standard for Metal Plate Connected Wood Truss Construction, as the specific design standard for metal plate connected wood trusses. This year, the new 5th Edition of the Florida Building Code was released and is now in effect statewide. 5, allowable seismic load values of Simpson Strong-Tie straps and ties used as hold-down connectors must be 75 percent of those in the evaluation report ESR-2613. Twist straps do not need to be wrapped over the truss to achieve the allowable load. 2 and 708. the Florida Building Code 2020, Sections 2303. Under the LARC, an engineered design in accordance with LARC Section R301. 1 Scope. See full list on attainablehome. 23. A summary of the three options is as follows: Option #1 – . 1 MTSM and HTSM Twist Straps. The Eighth Edition (2023) update to the Florida Building Code: Residential is a fully integrated publication that updates the Seventh Edition 2020 Florida Building Code: Residential using the latest changes to the 2021 International Residential Code® with customized amendments adopted statewide. 3 When any activity requiring a building permit that is applied for on or after July 1, 2008, and for which the estimated cost is $50,000 or more for a building that is located in the wind borne debris region as defined in s. (1) Roof trusses that are not design ed in accordance with Part 4 shall, (a) be capable of support ing a total ceiling load ( dead load plus live load) of 0. hparsons11 (Howard Parsons, HI 10148) March 18, 2020, 2:30pm 1. Truss design drawings, prepared in conformance to Sec-tion R802. 9 Preservative-Treated Wood. The HTSM resists both uplift and lateral forces. 140 miles per hour (63 m/s), Exposure B or C Maximum ground snow load of 70 psf (3352 Pa), with roof snow load, computed as 0. com Apr 24, 2022 · South Carolina. com. Wherever a strap is missing or an existing strap has fewer than four fasteners on each end, approved straps, ties or right angle brackets with a minimum uplift capacity of 500 pounds (740 kg) shall be installed that connect each rafter or truss to the top plate below. This brace will run perpendicular to the gable end and be nailed off to each of the next three to four trusses. fl. • Toenail-Clip Retrofits. Identification of the treating manufacturer. wood Roof Trusses. 2304. Jan 10, 2022 · TLDR; Hurricane Straps are vitally important to keep your roof trusses attached to your home. 25 inches wide with 3/4-inch wide flanges. 10. 1. 2 of the Florida Building Code , Building and that has an insured value of $300,000 or more or, if the building is uninsured or for which documentation of insured value is not presented, has a just valuation for the structure for Simpson Strong Tie H1 clip is one of the most commonly used. 8. ] If you are getting a new roof installed and your home has a value of $300,000 or more, Florida Building Codes 706. us. Allowable lateral loads are F 1 = 75 lb. They fasten to the wood member with 0. Heavy Twist Strap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL10456_R4_II_ESR-2613. The MSTM and HTSM twist straps are used to anchor wood trusses, rafters, or beams to masonry or concrete walls. DESCRIPTION: 4. Double Embedded Truss Anchor: Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Installation Instructions FL11473_R5_II_SIM202001 Sealed 2020-10-13. They will inspect your home and prepare a Wind Mitigation Inspection Report (OIR-B1-1802). 2 When a roof is replaced on a building that is located in the wind-borne debris region as defined in s. 5 acre facility in Homestead, under the brand name of Deco Truss. The uplift loads are pounds per lineal foot of building length. The species of wood treated. 17050 NE 19th Avenue North Miami Beach, FL 33162-3194 (305) 948-2965 (305) 919-3708 citynmb. May 31, 2015 · Wind Mitigation Form 1802 says to be considered a single wrap strap it has to be a “Metal connector consisting of a single strap that wraps over the top of the truss/rafter …”. Minimum roof slope of 3:12. 1 of the Florida Building Code ‐Existing Building, states that the retrofitting provisions outlined by Chapter 16, provide prescriptive solutions for the retrofitting of gable ends of buildings. Minimum edge distance for Titen Turbo screw is 1 1/2". 5 in the Florida Building Code, Building. Insurance providers in Florida offer premium discounts to homeowners who take proactive measures to make their homes more wind-resistant. Where windows are required to provide emergency escape and rescue openings in Group R-2 and R-3 occupancies and one- and two-family dwellings and townhouses regulated by the Florida Building Code, Residential, replacement windows shall be exempt from the requirements of Sections 1030. Instead, contact the office by phone or by traditional mail. Text: 202-937-0892 . Maximum ground snow load of 70 psf (3352 Pa), with roof snow load, computed as 0. If any item is not included identify the item and the reason for its exclusion in the narrative. 1609. 33 for framing spaced 16-inches on center and multiply by 2 for framing spaced 24-inches on center. Trussed roof system. Homes built before the 2002 Florida Building Code took effect weren’t required to have this extra nail that makes the roof more resistant to hurricane winds. The link above will take you to the website for the Municipal Code Corporation's page for the City of Sanibel Codes. (half gable) walls shall have end walls constructed of masonry, in accordance with this secti. There are other categories of roof to wall attachments found on the UMVI but Toe Nails, Wraps and Clips are the most common. Hialeah, FL. Fax: 305-694-0398. f slope of 3:12Maximum roof slope of 12:12 Maximum design wind speed. Simpson Strong-Tie offers a variety of connectors for cold-formed steel construction. Miami-Dade County NOA # FL 16294-R2. 8 mm; 1 pound per linear foot = 1. You can access specific City Codes using an index in the left pane, or you can use the site's search tool. Exception: Buildings and structures located within the high-velocity hurricane zone shall comply with the provisions of Sections 2204 through 2209 and 2214 through 2224. 13. EngineeringPlans. 5 of the Florida Building Code, Building The building is or would be assigned to risk category I or II in accordance with Table 1604. 6. apply when snow loads control the design are: Building width not great. and F 2 = 125 lb. 3 must be submitted. B. The new underlayment requirements are consistent with those recommended by the Insurance Institute for Business and Home Safety (IBHS) to create a sealed roof deck (SRD). We offer 3rd Nail and Hurricane Clip/Single Wrap retrofit (Roof To Wall Attachment) services that qualify homeowners for a 25%-35% annual reduction of their home insurance premium. Option #3 –. Remove The Soffit Outside Of The House. org, miamidade. 3)Roof component and cladding loads for buildings with mean roof heights of 60 feet or less have been rev. Middle (not end) unit. 12 to be preservative treated shall conform to the requirements of the applicable AWPA Standard U1 and M4 for the species, product, preservative and end use. 1 ‐Intent and purpose. NOTE: Table R602. 5, and 2321. 1395. Another component, which I would like to take … Continue reading "Florida Product Approvals Made Simple" May 28, 2015 · beam, on either side of the truss/rafter where each strap wraps over the top of the truss/rafter and is secured with a minimum of 2 nails on the front side, and a minimum of 1 nail on the opposing side, or 􀀀 Metal connectors consisting of a single strap that wraps over the top of the truss/rafter, is secured to the wall on 844-990-9797. In accordance with LABC Section 2305. 6: LFTA The only way to determine if your home needs hurricane strap retrofit installation is to have your home inspected by a licensed inspector. self-adhering polymer-modified bitumen underlayment complying with ASTM D1970 applied over the entire roof. 35 kPa plus two and two-thirds times the specified live roof load for 24 h, and. Truss design drawings shall include, at a minimum, the information specified below. The strap cannot have more than a half inch gap from the truss. Tel: 305-694-0397. If your home is valued at or over $300,000 and you don’t have three (3) nails on each strap, your roofing contractor will let you know (and 101. 2 shall be permitted within exterior wall assemblies of a 2-hour rating or less. 5 of the Florida Building Code, Building. This masonry twist strap is load rated for installation on both grout-filled concrete masonry units (GFCMU) and concrete. They fasten to the wood member with 10d common or 10d×1½" nails, and fasten to masonry with GENERAL. 101. 2), and the 2004 Florida Building Code, Building (Sections 2306. The first step to installing hurricane straps on an existing roof is to remove the soffit on the outside of the house. anchors shall be as listed, spaced as shown on details. underlayment in the 7th Edition (2020) Florida Building Code, Building (FBCB) and the Florida Building Code, Residential (FBCR) have been strengthened. To get a permit to build in South Carolina, you must have your straps inspected and approved by a licensed engineer. 488 kg/m; 1 mile per hour = 0. 3, 2321. </p> Apr 3, 2024 · Double Strap: Two separate metal pieces that wrap over the wall truss, each secured with three nails, providing even greater stability than a single strap. Roofing Checklist Florida Building Code 8th Edition (2023) Please include the following items in the order shown below. Method of drying after treatment. 2 and 2319. The distance between a fastener and the end of lumber shall be a minimum of 2 1 / 2 inches (64 mm). 4 Gable end and shed end walls. THE FLORIDA BUILDING CODE BROWARD COUNTY AMENDMENTS Looseleaf Supplement This Supplement contains all ordinances deemed advisable to be included at this time through: Amendment adopted on March 11, 2021, and effective March 22, 2021. They also attach windows and window sills to the structure. 2. Straps cannot have any corrosion or rust. 0105 345 and 346 15C-1. First printed in 2002, the Florida Building Code was developed as part of Florida’s response to the destruction caused by Hurricane Andrew and other hurricanes in the state. masonry shall have a minimum thickness of 8 inchesR4407. Feb 8, 2023 · If your Florida home was built before 2001, there’s a good chance your roof is missing a very important detail: a third nail in its metal hurricane truss straps. 3 and 1030. Truss span not greater than 36 feet. 4. 2 of the Florida Building Code, Building and Mar 31, 1999 · 298 (a) When anchors and straps are used for stabilizing the home in the longitudinal direction the strap must connect to a clip welded onto the I-beam or other device connected mechanically. Minimum edge distance in concrete block for Titen Turbo screws is 1 1/2". Section 1601. 1 and 2319. Specifics On Straps. Insurance Discounts and Credits. Nov 1, 2008 · Homeowners don’t have to spend more than 15% of the total cost of a reroof job on upgrading roof-wall connections. thirdnailguy@gmail. 2, 1030. 1 mm) and maximum span between lines of fasteners of 44 inches (1118 mm) shall be permitted for opening protection in Group R-3 or R-4 occupancy buildings with a mean roof height of 33 feet (10 058 mm) or less where Vult is 180 mph (80 m/s) or less. 1, shallbe provided with the building offi-cial and approved prior to installation. 7p g. Masonry chimneys and foundations shall be anchored at each floor, ceiling or roof line more than 6 feet (1829 mm) above grade with two 3 / 16 -inch by 1-inch (4. 2319. 1. The provisions of this chapter shall govern the materials, design, construction and quality of wood members and their fasteners. this product has been designed and tested to comply with the requirements of the florida building code 2017 edition including high velocity hurricane zone (hvhz). Truss design drawing shall be provided with the shipment of trusses delivered to the jobsite. 1503. ed significantly from ASCE 7-10. Fire suppression required by Section 438. all aluminum extrusions shall be 6063-t6 alloy with minimum yield strength of fy=31. 1(4) The 7th Edition (2020) update to the Florida Building Code: Existing Building Twist straps do not need to be wrapped over the truss to achieve the allowable load. Current code requires you to have three (3) nails instead of the old way of using two (2) nails on each strap. 6. 2301. 60 feet (ASCE 7-16 Section 30. 4 Seismic Anchorage. 2 of the Florida Building Code, Building and that has an insured value of $300,000 or more or, if the building is uninsured or for which documentation of insured value is not presented, has a just valuation for the structure for Exception: If an existing roofing system or roof section was built, repaired, or replaced in compliance with the requirements of the 2007 Florida Building Code, or any subsequent editions of the Florida Building Code, and 25 percent or more of such roofing system or roof section is being repaired, replaced, or recovered, only the repaired 2. Feb 3, 2021 · The top code violations according to one study conducted by the University of Florida, were strapping problems, trusses, connectors, and roof sheathing. Contact us today! LGT Restoration Services, LLC is a licensed general contractor that provides professional Truss Mitigation and Hurricane Retrofits to homeowners in Florida. 487. 4. An overflow scupper shall be sized in accordance with the Florida Building Code, Plumbing. The maximum area of each individual standard-unit panel shall be 250 square feet (23. The maximum area of each thin-unit panel shall be 150 square feet (13. The building is or would be assigned to risk category I or II in accordance with Table 1604. 9 m 2 ). The ends of wood girders entering exterior masonry or concrete walls shall be provided with a 1 / 2 -inch (12. gov, Intertek, CALADBS, Dr. E. Straps can be installed on the inside face of the wall. Wood structural panels with a minimum thickness of 7 / 16 inch (11. 7 mm). New construction question. pdf Verified By: ICC Evaluation Service, LLC Created by Independent Third Party: Evaluation Reports FL10456_R4_AE_ESR-2613. Pressure equalization lowers. 148"×3" or 0. An offset of more than 1/2-inch between connector and truss will void the strap discount. The code in South Carolina requires that all homes be built with hurricane straps. Hurricane straps are typically made of galvanized steel and come in various shapes and sizes, but all serve the same purpose of Raymond Building Supply operates three truss manufacturing locations in Florida, a 100,600 square foot facility in Auburndale, an 80,000 square foot facility in North Fort Myers and an 8. The inspector must rate it based on the weakest connection. The label shall contain: 1. It doesn’t say it necessarily has to be wra&hellip; The 7th Edition (2020) update to the Florida Building Code: Building is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Building using the latest changes to the 2018 International Building Code® with customized amendments adopted statewide. 4 mm. 2 of the Florida Building Code, Building and that has an insured value of $750,000 or more, or, if the building Florida Building Code, Building and 6th Edition (2017) Florida Building Code, Residential. 3 of the Florida Building Code, Building. Straps cannot have more than a 1/2" gap. Product Material: Strap: 16 Ga. ) Secure Ties or Straps to Roof Trusses With Screws. The bottoms of the clip engage with the top plate via four screws, creating a very secure connection between the roof and walls. 17. This is the panel that goes between the roof’s eaves and the walls of the home. Fire-retardant-treated wood framing complying with Section 2303. Flame spread index and smoke-developed index. 7. The distance between fasteners parallel to the grain (center All straps except the MTS30 have the twist in the center of the strap. ICC Digital Codes is the largest provider of model codes, custom codes and standards used worldwide to construct safe, sustainable, affordable and resilient structures. Because the outside roof corners get the most stress during high winds, the code requires those locations to be addressed first. Dec 31, 2020 · The 7th Edition (2020) update to the Florida Building Code: Residential is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Residential using the latest changes to the 2018 International Residential Code® with customized amendments adopted statewide. To do this, follow these steps: Use a screw that is the appropriate size and type for the job. If you have any questions, please contact 850. Option #2 –. The connector must be attached to the truss or rafter with a minimum of three nails. 8 mm by 25 mm) straps embedded not less than 12 inches (305 mm) into the chimney. 1 Tension Strap Capacity oximity to the edge of the roof. 2. Since Mar 18, 2020 · Local Inspection IssuesFlorida and SUNachi Inspectors. Remove Old Pages Insert New Pages Title page Title page v v The 7th Edition (2020) update to the Florida Building Code: Building is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Building using the latest changes to the 2018 International Building Code® with customized amendments adopted statewide. 305 m/s. [F. 148"×1½" nails, and fasten to masonry with Florida Building Code Menu General Users Order a Florida Building Code Book 7th Edition (2020) FBC 8th Edition (2023) FBC Code Resources and supplements to the FBC Find an Amendment or Declaratory Statement Find or Submit a Non-Binding Interpretation Petition for Nonbinding Advisory Opinion Find or Submit an Accessibility Waiver What's New FAQ If you're interested in Nu-Vue Products, please contact us at the numbers below. Twist straps do not have to be wrapped over the truss to achieve the load. . For roof uplift connections multiply by 1. S. The most common type of screw used is a hex head screw. It comes in various materials, including vinyl, aluminum, and wood. FIGURE 1707. 3. Maximum roof slope of 12:12. Strapping is hurricane straps that secure a building’s roof to the walls. 275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F. From roof truss and rafter connectors to twisted straps and hurricane ties, these connectors provide the uplift and lateral capacity necessary for a wide range of projects. f' m = 1,500 psi and f' c = 2,500 psi. If truss span is more than 20’, 75% of top and bottom chord members together shall be grade-marked, and one marked web member per truss. R607. 3. The maximum dimension between structural supports shall be 25 feet (7620 mm) in width or 20 feet (6096 mm) in height. 5, 2304. 2303. Florida Building Code, Building thand 7 Edition (2020) Florida Building Code, Residential. 1 applies to your property. Lumber, timber, plywood, piles and poles supporting permanent structures required by Section 2304. Dec 21, 2020 · A metal connector clip or strap must be installed from the wall to every truss or rafter. 12. Effective Date: December 31, 2020 Sep 23, 2013 · The Ontario Building Code | Wood Roof Trusses. Martin County, Florida Building Department 900 SE Ruhnke Street, Stuart, FL 34994 772-288-5916 www. com provides an independent way to search Florida, Miami Dade Product Approvals, & product evaluations from other listed agencies & is not affiliated with the State of Florida, Miami-Dade County, FloridaBuilding. J’s Engineering, or any other listed agency in any way. 33013. Method #1 is as follows: Start by nailing a two-by-four eight feet long to the gable end up near the ridge of the roof. All masonry structures with gable end and shed en. 1 Girder Ends. Product Description: The DTC embedded truss anchor consists of a steel strap to connect a wood member to a masonry wall. *Pursuant to Section 455. The final product should be able to withstand winds up to 110 mph (177 kph). Our services include: • 3rd Nail Services. See Titen Turbo screw information. With hurricane winds in Palm Beach County Florida, The Department of Building Safety has strict building codes that are enforced when a roof on an existing site-built, single-family residential structure is replaced or built, hurricane straps are required. Hurricane straps, also known as hurricane ties or clips, are metal connectors used to secure the roof of a structure to the walls, providing additional resistance against high winds during severe weather events. The Eighth Edition (2023) update to the Florida Building Code: Building is a fully integrated publication that updates the 7th Edition 2020 Florida Building Code: Building using the latest changes to the 2021 International Building Code® with customized amendments adopted statewide. After drilling the pilot holes, you can now secure the hurricane straps to the roof trusses with screws. Building code prior to the 1994 South Florida Building Code (building permit application date of 8/31/1994 or earlier in Miami-Dade and Broward Counties (HVHZ). The IBC becomes the governing code for the truss design and associated load paths if the FBC 2319. Type III construction is that type of construction in which the exterior walls are of noncombustible materials and the interior building elements are of any material permitted by this code. Chapter tabs are also included. 3 nails or more are required to be in clips and single wraps are required to have 2 nails in the face and one on the opposing side. The HTSM offers high-strength truss-to-masonry connections. See the Code Comparative Table for further information. when the following installation requirements are met. With our network of state-of-art facilities located in Lee, Miami-Dade and Polk Counties, we 2113. Our employees live in all the metropolitan areas of Florida, including Miami, Fort Lauderdale, and Tampa. Concrete shall have a minimum compressive strength of f' c = 2,500 psi. D TRUSSES PERMITS(MASTER PERMIT & SHOP DRAWINGS)9) Truss design drawings shall indicate the support and minimum bearing of the roof structural system, the permanent cross/lateral bracing, bracing to transfer member buckling forces to the structure There are two methods to brace the gable end truss. Cut some two-by-four blocking that will fit between each truss CODER4407. See note at right for search tips. Florida Building Code Administrative Chapter 1 is included. 5 of the Florida Building Code, Building when constructed under the Florida Building Code, Residential shall conform to Section 903. TRUSS GABLE END WALL WITH U-BENT STRAPS. LGT Restoration Services, LLC is a hurricane strap retrofit company servicing all of Florida. Complete and separate roofing systems, such as standing-seam metal roof systems, that are designed to transmit the roof loads directly to the building’s structural system and that do not rely on existing roofs and roof coverings for support, shall not require the removal of existing roof coverings. 25 inches long by 5. This Code states when re-roofing a home valued over $300,000 portions of the existing roof trusses are required to be retrofitted with the proper roof to wall connections. 22 Truss Anchor Strap Riveted Truss Anchor Strap Flat & Twisted Rafter Ties Butterfly Hanger Answer: The 2004 Florida Building Code, Residential (Section R802. The straps are used to transfer load between wood members and masonry walls. 3 Roof trusses shall be designed for a minimum live load of 30 psf (1436 Pa), a minimum dead load of 15 psf (718 Pa) on the top chord, and a minimum dead load of 10 psf (479 Pa) on the bottom chord; and wind loads per Chapter 16 of this code. Also, connectors that are not nailed to the truss/rafter with a minimum of three nails, or are offset so far as to reduce their structural effectiveness, are kicked back to the Toe Nails level. must provide the Department with an email address if they have one. 1055 East 29th Street. These are strictly regulated by building codes, because The distance between fasteners and the edge of lumber that is more than 2 inches (51 mm) thick in the direction of the fastener length shall be a minimum of 1 / 2 inch (12. 7pg The IBC becomes the governing code Florida Building Code . 11. pdf: 10456. 16-0201. 3 If truss span is 20’ or less, 50% of top and bottom chord members together shall be grade-marked. Where the roof design is such that water is not directed to the interior of the roof and Jan 1, 2021 · Step 1. C. martin. For SI: 1 inch = 25. May be installed on the inside face of the stud. Metal connectors consisting of a single strap that wraps over the top of the truss/rafter and is secured with a minimum of 2 nails on the front side and a minimum of 1 nail on the opposing side. Each clip is 5. Maximum design wind speed of 140 miles per hour (63 m/s), Exposure B or C. For example, on a $10,000 reroof, if you can’t tie down all the trusses for $1,500 or less, you Truss span not greater than 36 feet. Nu-Vue Industries, Inc. pdf Verified By: Keith Cullum, P. Reserved. A. 3 Interior Panels. 3 Gutters Gutters and leaders placed on the outside of buildings, other than Group R-3 , private garages and buildings of Type V construction, shall be of noncombustible material or a minimum of Schedule 40 plastic pipe. 1(7) Trusses grade mark 2319. The ceiling diaphragm of the retrofitted building in the area of the retrofit shall be comprised of minimum 1 / 2-inch gypsum board, minimum nominal 3 / 8-inch wood structural panels, or plaster. For SI: 1 foot = 304. 2 m 2 ). The hip rafter (commonly known as a “king jack”), the hip girder and the rafters/trusses adjacent to the hip girder that are not anchored with a strap having at least four fasteners on each end, shall be connected to the concrete masonry wall below using approved straps or right angle gusset brackets with a minimum uplift capacity of 500 The Effective Date for the Florida Building Code, 8th Edition (2023), is December 31, 2023. B. The name of the fire-retardant treatment. 0107 , 347 F. The 7th Edition (2020) update to the Florida Building Code: Residential is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Residential using the latest changes to the 2018 International Residential Code® with customized amendments adopted statewide. No visible severe corrosion of the connectors. 0 ksi unless it is specified. This rugged clip cradles the truss or rafter on two sides. 1994 South Florida Building Code (building permit application date of 9/1/1994 or later in Miami-Dade and Broward Counties (also known as the High Velocity Hurricane Zone (HVHZ)). cm bh ic rk lx kl ri pp yn ee